| Code/Variants |
Frame size |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71 |
80 |
90 |
100 |
112 |
132 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
| +403 |
Degree of protection IP56. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +404 |
Degree of protection IP56, without fan and fan cover. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +434 |
Degree of protection IP56, open deck. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
| +520 |
Motor protection cover made of glass fiber. Vertical motor, shaft down. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
- |
- |
| +783 |
Labyrinth sealing at D-end. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
○ |
○ |
○ |
○ |
| +784 |
Gamma-seal at D-end. |
● |
● |
● |
● |
● |
● |
○ |
○ |
- |
○ |
○ |
- |
- |
- |
- |
- |
- |
| Rating & instruction plates |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| +002 |
Restamping voltage, frequency and output, continuous duty. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +004 |
Additional text on std rating plate (max 12 digits on free text line). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +095 |
Restamping output (maintained voltage, frequency), intermittent duty. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +098 |
Stainless rating plate. |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
| +126 |
Tag plate |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +135 |
Mounting of additional identification plate, stainless. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +138 |
Mounting of additional identification plate, aluminium. |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
| +139 |
Additional identification plate delivered loose. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +159 |
Additional plate with text "Made in ...." |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +160 |
Additional rating plate affixed. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +161 |
Additional rating plate delivered loose. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +163 |
Frequency converter rating plate. Rating data according to quotation. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +181 |
Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +333 |
Not for use in the USA |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
| +528 |
Rating plate sticker |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +818 |
Restamping as generator |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| Shaft & rotor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| +069 |
Two shaft extensions according to catalog drawings. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +070 |
Special shaft extension at D-End, standard shaft material |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +131 |
Motor delivered with half key (key not exceeding shaft diameter) |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +155 |
Cylindrical shaft extension, D-end, without key-way. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +164 |
Shaft extension with closed keyway |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
● |
● |
● |
● |
- |
- |
| +165 |
Shaft extension with open keyway |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
○ |
○ |
○ |
○ |
○ |
○ |
| +410 |
Shaft material stainless steel |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +591 |
Special shaft extension according to customer specification. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +600 |
Special shaft extension at N-end, standard shaft material. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +630 |
Shaft material certificate 3.1/3.2 according to EN10204:2004 |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| Standards and Regulations |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| +208 |
Fulfilling Underwriters Laboratories (UL), listed requirements |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +331 |
IE1 motor not for sale for use in EU |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +421 |
VIK design (Verband der Industriellen Energie- und Kraftwirtschaft e.V.). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
| +509 |
Fulfilling US Integral Horsepower Motor Rule (IHP). |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
| +540 |
China energy label |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +543 |
Australian MEPS |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
| +687 |
Fulfilling energy efficiency requirements for Canada |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
| +822 |
WIMES 3.03i6 Compliant Design for DOL operation |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +823 |
WIMES 3.03i6 Compliant Design for VSD operation |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| Stator winding temperature sensors |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| +120 |
KTY 84-130 (1 per phase) in stator winding. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +121 |
Bimetal detectors, break type (NCC), (3 in series), 130 ºC, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +122 |
Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +123 |
Bimetal detectors, break type (NCC), (3 in series), 170 ºC, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +124 |
Bimetal detectors, break type (NCC), (3 in series), 140 ºC, in stator winding |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +125 |
Bimetal detectors, break type (NCC), (2x3 in series), 150 ºC, in stator winding |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +127 |
Bimetal detectors, break type (NCC), (3 in series, 130 ºC & 3 in series, 150 ºC), in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| ○ = Included as standard │ ● = Available as option │ - = Not applicable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Code/Variants |
Frame size |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71 |
80 |
90 |
100 |
112 |
132 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
| +435 |
PTC - thermistors (3 in series), 130 ºC, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +437 |
PTC - thermistors (3 in series), 170 ºC, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +438 |
PTC - thermistors (3 in series), 190 ºC, in stator winding |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +439 |
PTC - thermistors (2x3 in series), 150 ºC, in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +441 |
PTC - thermistors (3 in series, 130 ºC & 3 in series, 150 ºC), in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +442 |
PTC - thermistors (3 in series, 150 ºC & 3 in series, 170 ºC), in stator winding |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +445 |
Pt100 2-wire in stator winding, 1 per phase |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +446 |
Pt100 2-wire in stator winding, 2 per phase |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +502 |
Pt100 3-wire in stator winding, 1 per phase |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +503 |
Pt100 3-wire in stator winding, 2 per phase |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +511 |
PTC thermistors (2 x 3 in series), 130 ºC, in stator winding |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +515 |
Pt100 3-wire in stator winding, 3 per phase |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| Terminal box |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| +015 |
Motor supplied in D connection. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +017 |
Motor supplied in Y connection. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +019 |
Larger than standard terminal box. |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
● |
● |
● |
● |
- |
- |
| +020 |
Detached terminal box. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +021 |
Terminal box LHS (seen from D-end). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
| +022 |
Cable entry LHS (seen from D-end). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +157 |
Terminal box degree of protection IP65. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
| +180 |
Terminal box RHS (seen from D-end). |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
| +230 |
Standard metal cable gland. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
| +277 |
Cable sealing end unit, size small for C-opening |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
- |
- |
- |
- |
- |
| +278 |
Cable sealing end unit, size medium for D-opening |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
| +279 |
Cable sealing end unit, size large for D-opening |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
| +292 |
Adapter C-C |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
- |
- |
- |
- |
- |
| +293 |
Adapter D-D |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
- |
- |
- |
| +294 |
Adapter E-D |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
| +295 |
Adapter E-2D |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
○ |
○ |
| +296 |
Adapter E-3D |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
| +351 |
Terminal block turned according to cable entry |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
| +375 |
Standard plastic cable gland |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +376 |
Two standard plastic cable glands |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +380 |
Separate terminal box for temperature detectors, std. material |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +400 |
4 x 90 degr turnable terminal box. |
● |
● |
● |
● |
● |
● |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
- |
- |
- |
| +413 |
Extended cable connection, no terminal box. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +418 |
Separate terminal box for auxiliaries, standard material. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +444 |
Adapter E-2E |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
| +447 |
Top mounted separate terminal box for monitoring equipment. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +466 |
Terminal box at N-end. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +467 |
Lower than standard terminal box and rubber extended cable. Cable length 2 m |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +468 |
Cable entry from D-end. |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
● |
● |
● |
● |
● |
- |
- |
| +469 |
Cable entry from N-end. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
| +526 |
Existing cable entries plugged |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
○ |
● |
● |
- |
- |
- |
| +553 |
Terminal box degree of protection IP66. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
| +554 |
Cast iron flange for cable glands drilled and tapped according to order. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +557 |
Nickel plated cable glands mounted according to order. |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +565 |
Adapter for terminal box on the side (RHS) |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
- |
- |
| +566 |
Adapter for terminal box on the side (LHS) |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
- |
- |
| +567 |
Separate terminal box material: cast Iron |
- |
- |
- |
- |
- |
- |
○ |
○ |
○ |
○ |
○ |
● |
● |
● |
● |
● |
● |
| +568 |
Separate terminal box for heating elements, std. material |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +569 |
Separate terminal box for brakes |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +624 |
Prepared for inch cable glands according to BSPP standard. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +727 |
Stainless steel flange for cable glands drilled and tapped according to order. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +730 |
Prepared for NPT cable glands. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +731 |
Two standard metal cable glands. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +742 |
Protective cover for accessory terminal block in main terminal box. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +743 |
Non-drilled cast iron flange for cable glands |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +744 |
Stainless steel non-drilled flange for cable glands. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| ○ = Included as standard │ ● = Available as option │ - = Not applicable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Code/Variants |
Frame size |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
71 |
80 |
90 |
100 |
112 |
132 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
450 |
500 |
| +745 |
Painted steel flange equipped with nickel plated brass cable glands |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +746 |
Stainless steel cable flange equipped with standard nickel plated brass cable glands |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| Testing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| +145 |
Type test report from a catalogue motor, 400V 50Hz. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +146 |
Type test with report for one motor from specific delivery batch. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +148 |
Routine test report. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +149 |
Test according to separate test specification. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
| +150 |
Customer witnessed testing. Specify test procedure with other codes. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +222 |
Torque/speed test, type test and multi-point load test with report for one motor from specific delivery batch. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +560 |
Shaft voltage test, for one motor from specific delivery batch. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +561 |
Overspeed test,for one motor from specific delivery batch |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +562 |
Overvoltage test, for one motor from specific delivery batch. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +760 |
Vibration level test |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +761 |
Vibration spectrum test for one motor from specific delivery batch. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +762 |
Noise level test for one motor from specific delivery batch. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +763 |
Noise spectrum test for one motor from specific delivery batch. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +764 |
Test for one motor from specific delivery batch with ABB frequency converter available at ABB test field.ABB standard test procedure. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| Variable speed drives |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| +429 |
Separate motor cooling (fan top, N-end) and 1024 pulse tacho (Leine & Linde 861) mounted. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +470 |
Prepared for hollow shaft pulse tacho (L&L equivalent). |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +472 |
1024 pulse tacho (L&L 861007455-1024). |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +473 |
2048 pulse tacho (L&L 861007455-2048). |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +474 |
Separate motor cooling (axial fan, N-end) and prepared for hollow shaft tacho (L&L equivalent) |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +476 |
Separate motor cooling (axial fan, N-end) and 1024 pulse tacho (L&L 861007455-1024) |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +477 |
Separate motor cooling (axial fan, N-end) and 2048 pulse tacho (L&L 861007455-2048) |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +478 |
Separate motor cooling (fan on top, N-end) and prepared for hollow shaft tacho (L&L equivalent) |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +479 |
Mounting of other type of pulse tacho with shaft extension, tacho not included. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +486 |
Separate motor cooling (fan top, N-end) and prepared for DC-tacho. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +510 |
Separate motor cooling (fan top, N-end) and 2048 pulse tacho (Leine & Linde 861) mounted. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +582 |
1024 pulse tacho, GHK912-GBR-1024, BEI IDEACOD |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +583 |
2048 pulse tacho, GHK912-GBR-2048, BEI IDEACOD |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
| +588 |
Shaft grounding device |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +658 |
Special tacho mounted, price category 1 |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +659 |
Special tacho mounted, price category 2 |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +660 |
Special tacho mounted, price category 3 |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +701 |
Insulated bearing at N-end. |
- |
- |
- |
- |
- |
- |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| +702 |
Insulated bearings at both ends |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
- |
- |
- |
- |
- |
- |
| +704 |
EMC cable entry. |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
| ○ = Included as standard │ ● = Available as option │ - = Not applicable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|