| Code/Variants |
Frame size |
|||||||||||||
| 56 | 63 | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | ||
| Administration |
||||||||||||||
| +531 | Sea freight packing. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +601 | Special Sea freight packing | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| Balancing |
||||||||||||||
| +052 | Vibration acc. to Grade A (IEC 60034-14). | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +426 | Half key balancing. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| Bearings and Lubrication |
||||||||||||||
| +037 | Roller bearing at D-end. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +039 | Cold-resistant grease. | - | - | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +040 | Heat-resistant grease. | - | - | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +041 | Bearings regreasable via grease nipples. | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +042 | Locked D-end | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +043 | SPM compatible nipples for vibration measurement. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +057 | 2RS bearings at both ends. | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +188 | 63-series bearing in D-end. | - | - | - | - | ● | ○ | ○ | ● | ○ | ○ | ○ | ○ | ○ |
| +194 | 2Z bearings greased for life at both ends | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +195 | Bearings greased for life | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +593 | Bearings grease suitable for food and beverage industry. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +781 | Lubrication plate put aside | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +795 | Lubrication information plate | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +798 | Stainless steel grease nipples. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| Brakes |
||||||||||||||
| +086 | Reconnection of brake for separate ac supply. | - | - | ● | ● | ● | ● | ● | ● | - | - | - | - | - |
| +088 | Brake with mechanical release. | - | - | ● | ● | ● | ● | ● | ● | - | - | - | - | - |
| +288 | Brake motor with voltage code S for the motor and separate supply of the brake for voltage corresponding to code D. |
- | - | ● | ● | ● | ● | ● | ● | - | - | - | - | - |
| +289 | Brake motor with voltage code D for the motor and separate supply of the brake for voltage corresponding to code S. |
- | - | ● | ● | ● | ● | ● | ● | - | - | - | - | - |
| +298 | Brake motor for 460V with voltage code S and D | - | - | - | - | ● | ● | ● | ● | - | - | - | - | - |
| +843 | DC Brake. (Sizes 71-132 available as premodified motors with 843) | - | - | ○ | ○ | ○ | ○ | ○ | ○ | ● | ● | - | - | - |
| Branch standard designs |
||||||||||||||
| +178 | Stainless steel / acid proof bolts. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +210 | Special electric design (SEL design) | - | - | - | - | - | - | - | - | - | - | - | ● | ● |
| +217 | Cast iron D-end shield (on aluminum motor). | - | - | - | - | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ |
| +232 | Cast iron N-end shield (on aluminium motor) | - | - | - | - | - | - | - | - | ○ | ○ | ○ | ○ | ○ |
| +425 | Corrosion protected stator and rotor core. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Cooling system |
||||||||||||||
| +046 | Two-directional fan. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +053 | Metal fan cover. | - | - | ● | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ |
| +068 | Light alloy metal fan. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +183 | Separate motor cooling (fan axial, N-end). | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +205 | Non metalic fan. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +792 | Metal fasteners for fan cover. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| Documentation |
||||||||||||||
| +141 | Binding 2D main dimension drawing. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Drain holes | ||||||||||||||
| +065 | Plugged existing drain holes. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| Earthing Bolt |
||||||||||||||
| +067 | External earthing bolt. | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| ○ = Included as standard │ ● = Available as option │ - = Not applicable |
||||||||||||||
| Code/Variants |
Frame size | |||||||||||||
| 56 | 63 | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | ||
| Hazardous Environments |
||||||||||||||
| +335 | Ex t, Dust group III B T125C Dc, IP5X (non-conductive dust) acc. IEC/EN60079-31. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +336 | Ex t, Dust group III C T125 Db, IP6X (conductive dust) acc. IEC/EN60079-31. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +338 | Rated for gas or dust, Ex ec IIC T3 Gc / Ex tc IIIB T125C Dc (non-nocductive dust), IP5X. | - | - | - | - | ○ | ○ | ○ | ○ | - | - | - | - | - |
| +339 | Rated for gas or dust, Ex ec IIC T3 Gc / Ex tc IIIC T125C Dc (conductive dust), IP6X. | - | - | - | - | ○ | ○ | ○ | ○ | - | - | - | - | - |
| +456 | Ex ec IIC T3 Gc acc. IEC/EN 60079-7 with certificates. | - | - | - | - | ○ | ○ | ○ | ○ | ● | ● | ● | ● | ● |
| Heating elements |
||||||||||||||
| +450 | Heating element, 100-120 V. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +451 | Heating element, 200 - 240 V. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Marine |
||||||||||||||
| +096 | Fulfilling Lloyds Register of Shipping (LR) requirements, without certificate (non-essential duty only). | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +186 | Fulfilling Det Norske Veritas (DNV) requirements, without certificate. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +492 | Fulfilling Registro Italiano Navale (RINA) requirements, without certificate. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +493 | Fulfilling China Classification Societies (CCS) requirements (Beijing), without certificate. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +496 | Fulfilling Bureau Veritas (BV) requirements, without certificate(non-essential duty only). | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +675 | Fulfilling American Bureau of Shipping (ABS) requirements, without certificate (non-essential duty only). | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Mounting arrangements |
||||||||||||||
| +007 | IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +008 | IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - |
| +009 | IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +047 | IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). | ● | ● | ● | ● | ● | ● | ● | ● | ● | - | - | - | - |
| +048 | IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). | - | - | ● | ● | ● | ● | ● | ● | - | - | - | - | - |
| +066 | Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101). | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +200 | Flange ring holder. | - | - | ● | ● | ● | ● | ● | ● | - | - | - | - | - |
| +223 | Flange ring FF 115. | - | - | ● | ● | ● | - | - | - | - | - | - | - | - |
| +224 | Flange ring FT 115. | - | - | ● | ● | ● | - | - | - | - | - | - | - | - |
| +226 | Flange ring FF 130. | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | - |
| +227 | Flange ring FT 130. | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | - |
| +233 | Flange ring FF 165. | - | - | - | ● | ● | ● | ● | ● | - | - | - | - | - |
| +234 | Flange ring FT 165. | - | - | ● | ● | ● | ● | ● | - | - | - | - | - | - |
| +243 | Flange ring FF 215. | - | - | - | - | - | - | ● | ● | - | - | - | - | - |
| +253 | Flange ring FF 265. | - | - | - | - | - | - | - | ● | - | - | - | - | - |
| +255 | Flange FF 265. | - | - | - | - | - | - | - | ● | - | - | - | - | - |
| +260 | Flange FT 115. | - | - | - | - | ● | - | - | - | - | - | - | - | - |
| Painting |
||||||||||||||
| +114 | Special paint color, standard grade. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +714 | Customer painting specification | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | |
| Protection |
||||||||||||||
| +005 | Protective roof. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +072 | Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +074 | Degree of protection IP55. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +158 | Degree of protection IP65. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +250 | Degree of protection IP66. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +403 | Degree of protection IP56. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +784 | Gamma-seal at D-end. | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| ○ = Included as standard │ ● = Available as option │ - = Not applicable |
||||||||||||||
| Code/Variants |
Frame size | |||||||||||||
| 56 | 63 | 71 | 80 | 90 | 100 | 112 | 132 | 160 | 180 | 200 | 225 | 250 | ||
| Rating & instruction plates |
||||||||||||||
| +002 | Restamping voltage, frequency and output, continuous duty. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +003 | Individual serial number. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +004 | Additional text on std rating plate (max 12 digits on free text line). | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +095 | Restamping output (maintained voltage, frequency), intermittent duty. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +098 | Stainless steel rating plate. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +126 | Tag plate. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +135 | Mounting of additional identification plate, stainless steel. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +138 | Mounting of additional identification plate, aluminium. | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +159 | Additional plate with text “Made in ”. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +160 | Additional rating plate affixed. | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +161 | Additional rating plate delivered loose. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +162 | Rating plate fixed to stator | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +163 | Frequency converter rating plate. Rating data according to quotation. | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +181 | Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +332 | Baldor Catalogue #. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Shaft & rotor |
||||||||||||||
| +164 | Shaft extension with closed keyway | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| Standards and Regulations |
||||||||||||||
| +208* | Fulfilling Underwriters Laboratories (UL), listed requirements. | - | - | - | ○ | ○ | ○ | ○ | ○ | ● | ● | ● | ● | ● |
| +331 | Motor not for sale for use in EU. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +509* | Fulfilling US Integral Horsepower Motor Rule (IHP). | - | - | - | ○ | ○ | ○ | ○ | ○ | ● | ● | ● | ● | ● |
| +538 | CE mark | - | - | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +540* | China energy label. | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +543 | Australian MEPS. | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +544 | Australian HE MEPS | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +586 | UKCA mark | - | - | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +598 | Universal motor | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● |
| +687 | Fulfilling energy efficiency requirements for Canada | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● |
| Stator winding temperature sensors |
||||||||||||||
| +122 | Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator winding. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +436 | PTC - thermistors (3 in series), 150 ºC, in stator winding. | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +445 | Pt100 2-wire in stator winding, 1 per phase. | - | - | - | - | - | - | - | ● | ● | ● | ● | ● | ● |
| Terminal box |
||||||||||||||
| +015 | Motor supplied in D connection. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +017 | Motor supplied in Y connection. | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +018 | Small terminal box | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +019 | Larger than standard terminal box. | - | - | - | - | - | - | - | - | - | - | ● | ● | ● |
| +021 | Terminal box LHS (seen from D-end). | - | - | - | - | - | - | - | - | - | - | ● | ● | ● |
| +022 | Cable entry LHS (seen from D-end). | - | - | - | - | - | - | - | - | - | - | ● | ● | ● |
| +180 | Terminal box RHS (seen from D-end). | - | - | - | - | - | - | - | - | - | - | ● | ● | ● |
| +230 | Standard metal cable gland. | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +375 | Standard plastic cable gland. | - | - | ● | ● | ● | ● | ● | ● | - | - | - | - | - |
| +465 | Terminal box on top. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| +731 | Two standard metal cable glands. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +738 | Prepared for metric cable glands. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| Testing |
||||||||||||||
| +145 | Type test report from a catalogue motor, 400V 50Hz. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| +148 | Routine test report. | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Variable speed drives |
||||||||||||||
| +701 | Insulated bearing at N-end. | - | - | - | - | - | - | - | - | ● | ● | ● | ● | ● |
| +704 | EMC cable entry. | - | - | - | - | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Y/D starting |
||||||||||||||
| +023 | 6 terminals (for Y/D start, single speed), in terminal box. | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
| ○ = Included as standard │ ● = Available as option │ - = Not applicable |
||||||||||||||
| * Valid only for registered motors (Motor type M3AA with generation K) |
||||||||||||||